<Toc> <2. Initial Settings>
2-5
IM 05D01D02-41E
■ Instrument Input Range Codes
Input Type
Instrument Input
Range Code
Instrument
Input Range
Measurement Accuracy
OFF
1
-200 to 1370⬚C
Set the data item PV Input Type "IN" to the OFF option to leave the PV input
type undefined.
2
K
J
4
5
T
6
⫾0.1% of instrument range ⫾1 digit for temperatures
equal to or higher than 0
⬚
C
⫾0.2% of instrument range ⫾1 digit for temperatures
below 0
⬚
C
⫾0.1% of instrument range ⫾1 digit for temperatures
equal to or higher than 0
⬚
C
⫾0.2% of instrument range ⫾1 digit for temperatures
below 0
⬚
C
B7
⫾0.15% of instrument range ⫾1 digit at 400
⬚
C or more
⫾5% of instrument range ⫾1 digit at less than 400
⬚
C
S
8
R
9
⫾0.15% of instrument range ⫾1 digit
N
10
⫾0.1% of instrument range ⫾1 digit
⫾0.25% of instrument range ⫾1 digit for temperatures
below 0
⬚
C
E
11
L(DIN)
12
13
U(DIN)
14
W
15
⫾0.2% of instrument range ⫾1 digit
Platinel 2
16
⫾0.1% of instrument range ⫾1 digit
PR20-40 17
⫾0.5% of instrument range ⫾1 digit at 800
⬚
C or more
No accuracy is guaranteed at less than 800
⬚
C
Thermocouple
Unspecified
W97Re3-
W75Re25
18
⫾0.2% of instrument range ⫾1 digit
30
⫾0.1% of instrument range ⫾1 digit (Note 1) (Note 2)
JPt100
31
⫾0.2% of instrument range ⫾1 digit (Note 1)
35
36
⫾0.1% of instrument range ⫾1 digit (Note 1) (Note 2)
RTD
Pt100
37
⫾0.2% of instrument range ⫾1 digit (Note 1)
0.4 to 2 V
40
Standard
signal
1 to 5 V 41
0 to 2 V 50
0 to 10 V 51
0.400 to 2.000 V
1.000 to 5.000 V
0.000 to 2.000 V
0.00 to 10.00 V
-10 to 20 mV
55 -10.00 to 20.00 mV
DC voltage
0 to 100 mV
56 0.0 to 100.0 mV
⫾0.1% of instrument range ⫾1 digit
The read-out range can be scaled between -1999 to
9999.
3
-300 to 2500⬚F
-199.9 to 999.9⬚C
0 to 2300⬚F
-199.9 to 500.0⬚C
-199.9 to 999.9⬚F
-199.9 to 999.9⬚C
-300 to 2300⬚F
-199.9 to 400.0⬚C
-300 to 750⬚F
0.0 to 400.0⬚C
-199.9 to 750.0⬚F
0 to 1800⬚C
32 to 3300⬚F
0 to 1700⬚C
32 to 3100⬚F
0 to 1700⬚C
32 to 3100⬚F
-200 to 1300⬚C
-300 to 2400⬚F
-199.9 to 999.9⬚C
-300 to 1800⬚F
-199.9 to 900.0⬚C
-300 to 1300⬚F
-199.9 to 400.0⬚C
-300 to 750⬚F
0.0 to 400.0⬚C
-199.9 to 750.0⬚F
0 to 2300⬚C
32 to 4200⬚F
0 to 1390⬚C
32 to 2500⬚F
0 to 1900⬚C
32 to 3400⬚F
0 to 2000⬚C
32 to 3600⬚F
-199.9 to 500.0⬚C
-199.9 to 999.9⬚F
-150.0 to 150.0⬚C
-199.9 to 300.0⬚F
-199.9 to 850.0⬚C
-300 to 1180⬚F
-199.9 to 500.0⬚C
-199.9 to 999.9⬚F
-150.0 to 150.0⬚C
-199.9 to 300.0⬚F
* Performance in the standard operating condition (at 23⫾2⬚C, 55⫾10%RH, and 50/60Hz power frequency)
Note 1: The accuracy is ⫾0.3⬚C of instrument range ⫾1 digit for a temperature range from 0⬚C to 100⬚C.
Note 2: The accuracy is ⫾0.5⬚C of instrument range ⫾1 digit for a temperature range from -100⬚C to 200⬚C.
* To receive a 4-20 mA DC signal, select a standard signal of 1 to 5 V DC and connect it to a 250 ⍀ resistor. This resistor
is optional.
Model: X010-250-2 (resistor with M3.5 crimp-on terminal lugs)
NOTE
The controller may automatically initialize the registered operating parameter setpoints if
any change is made to the data item PV Input Type (IN), Maximum Value of PV Input
Range (RH), Minimum Value of PV Input Range (RL), PV Input Decimal Point Position
(SDP), Maximum Value of PV Input Scale (SH) or Minimum Value of PV Input Scale (SL).
After a change has been made to any of these data items, be sure to verify the registered
operating parameter setpoints to ensure that they are correct. If any data item has been
changed to its default, set it to a required value.