EasyManua.ls Logo

YOKOGAWA FX103 User Manual

YOKOGAWA FX103
263 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
User’s
Manual
Yokogawa Electric Corporation
Model FX103/FX106/FX112
FX100
Model FX103/FX106/FX112
FX100
IM 04L20A01-01E
4th Edition

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the YOKOGAWA FX103 and is the answer not in the manual?

YOKOGAWA FX103 Specifications

General IconGeneral
BrandYOKOGAWA
ModelFX103
CategoryController
LanguageEnglish

Summary

Safety Precautions

Precautions Related to the Protection, Safety, and Alteration of the Product

Details safety symbols, handling precautions, and product modification warnings.

Chapter 1 Explanation of Functions

1.1 Overview of the FX100

Gives a general overview of the FX100's functions, including measurement input and alarms.

1.2 Functions of the Input Section

Explains the various input types, computations, and measurement ranges supported by the FX100.

1.3 Alarm Function

Describes how alarms are generated, configured, and indicated on the FX100.

1.4 Display Function

Details the FX100's display capabilities, including screen sections, data views, and indications.

1.5 Data Storage Function

Explains the types of data the FX100 can create and how to save them to memory or external media.

Chapter 2 Installation and Wiring

2.1 Handling Precautions

Provides essential precautions for handling the FX100 and external storage media safely.

2.2 Installation

Details instructions for installing the FX100, including location and panel mounting procedures.

2.3 Measurement Input Terminal Wiring

Guides on wiring measurement input terminals, ensuring proper connections and noise prevention.

2.5 Wiring the Power Supply

Provides instructions and precautions for wiring the FX100's power supply.

Chapter 3 Names of Parts, Display Modes, and Common Operations

3.1 Names of Parts and Functions

Identifies and describes the functions of the FX100's front panel and rear panel components.

3.2 Basic Key Operations

Details how to switch operation modes and use the FX100's keys for basic navigation and control.

Chapter 4 Measurement Input and Alarm Setup Operations

4.1 Setting Parameters Related to Measurement Inputs

Details setting parameters for measurement inputs, including A/D time, scan interval, and input types.

4.2 Setting Alarm Related Parameters

Covers setting alarms, alarm output relay actions, alarm indication, and hysteresis for each channel.

4.3 Setting Pulse Input (/PM1 Option)

Explains how to configure pulse input terminals for counting pulses and calculating values.

Chapter 5 Operations on the Operation Screens

5.1 Displaying Measured Data in Waveform, Numerical Values, or Bar Graph (Trend, Digital, and Bar Graph Screens)

Guides on displaying measured data in various formats like trend waveforms, digital values, and bar graphs.

5.4 Displaying Measured Data Previously Acquired (Historical Trend)

Describes methods for displaying historical data trends, including scrolling and zooming.

Chapter 7 Data Save/Load Operations

7.1 Setting Measured Data Acquisition to the Internal Memory and Data Save to the External Storage Medium

Covers setting up data acquisition to internal memory and saving data to external storage.

7.2 Starting/Stopping the Acquisition to the Internal Memory

Explains how to start, stop, and apply triggers for data acquisition to the internal memory.

7.3 Saving Data to the External Storage Medium (Only for Models with an External Storage Medium Drive)

Details how to save measured data from internal memory to external storage media.

7.9 Saving and Loading Setup Data

Explains how to save and load the FX100's setup data to/from external storage.

Chapter 8 Computation and Report Function Related Operations (/M1 or /PM1 Option)

8.1 Assigning Computation Channels and Setting Computing Equations, Constants and Tags

Guides on assigning computation channels, setting equations, constants, and tags for data processing.

8.2 Starting, Stopping, and Resetting the Computation

Explains how to start, stop, and reset computations, and clear computation data dropout indications.

8.3 Setting Computation Channel Alarms

Details how to set alarms for computation channels, including types, values, and relay outputs.

8.4 Setting the Timer for Statistical Computations (TLOG Computation) and Data Save (TLOG Data)

Guides on setting timers for TLOG computation and data save at specified intervals.

8.6 Creating Reports

Details how to set report types, channels, creation time, and sum scales for generating reports.

Chapter 10 Troubleshooting

10.1 A List of Messages

Lists various error codes and messages with their explanations and countermeasures for troubleshooting.

10.2 Troubleshooting Flow Chart

Offers flowcharts to systematically diagnose and resolve issues with the instrument's operation and display.

Chapter 11 Maintenance

11.2 Calibration

Provides recommendations and procedures for calibrating the FX100 to ensure measurement accuracy.

Chapter 12 Specifications

12.1 Input Specifications

Lists detailed specifications for FX100 inputs, including types, ranges, and scan intervals.

Appendix 2 Meaning and Syntax of Equations

Appendix 3 Pulse Measurement Setting Example (Pulse Sum Value Reset If It Exceeds a Fixed Value) (/PM1 Option)

Appendix 6 List of Parameters

Related product manuals