2. HANDLING PRECAUTIONS
This section describes the precautions to follow
when handling the product. Be sure to read this
section before using the product.
For information other than that described in this
section, refer to the related section.
If you have any problems or questions, contact
your nearest YOKOGAWA service center or sales
representative.
2.1 Checking Model and
Specications
This instrument is inspected thoroughly before it is
shipped from the factory. When this instrument is
delivered to the installation site, check its external
appearance for damage, and make sure that all
parts for installation are provided.
Be sure that you have your model number (MODEL) and
serial number (No.) available when contacting Yokogawa.
The model code and specications given on the
nameplate are those current when this product was
shipped from the factory.
F0201.ai
Figure 2.1(a) Example of Nameplate (Integral Type)
Remote Sensor
F0202.ai
Remote Transmitter
F0205.ai
Figure 2.1(b) Example of Nameplate (Remote Type)
2.2 Transportation and Storage
Precautions
To prevent damage to the vortex owmeter due to
accidents during transportation, it should be carried
in its original packing condition.
Deterioration of insulation, corrosion or other
abnormalities may occur due to unexpected
situations if the vortex owmeter is stored for a long
period of time after it is delivered to the user site.
When it is anticipated that the vortex owmeter
will be stored for a long time, pay attention to the
following points.
(1) The vortex owmeter should be stored in its original
packing condition in the storage location.
(2) Select a storage location that fullls the following
conditions:
A place where it will not be exposed to rain or
water
A place subject to minimal vibrations or shocks
Temperature and humidity levels should be as
follows: The preferred ambient temperature and
humidity levels are +25°C and approximately 65%
RH.
Ambient temperature: -40 to +85°C
Humidity: 0 to 100% RH (no condensation)
(3) When storing a vortex owmeter after use,
completely clean the owmeter to ensure that there
is no measured uid remaining in its piping line and
on the shedder bar.
(4) If the vortex owmeter is carried to the installation
site and is stored without being installed, rain
water might get inside and impair the instrument's
performance. Install, wire and perform other
installation work immediately after transporting the
vortex owmeter to the installation site.
<2. Handling Precautions>
8
IM 01F07A01-01EN

Table of Contents

Other manuals for YOKOGAWA VY Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the YOKOGAWA VY Series and is the answer not in the manual?

YOKOGAWA VY Series Specifications

General IconGeneral
BrandYOKOGAWA
ModelVY Series
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals