Page – 102/139 AFFZP0BB – ACE3 – User Manual
Troubleshooting
- Check if the SET KEY VOLTAGE parameter in the ADJUSTMENT list is set
in accordance with the key voltage.
- Check if the key voltage is ok using a voltmeter, if not check the wiring.
- In case the problem is not solved, replace the logic board.
48) WRONG SET BATTERY
Cause
The measured battery voltage is not the right one for the inverter.
Troubleshooting
- Check if the battery voltage (measured between the +Batt and -Batt
terminals of the inverter) is ok using a voltmeter, if not check the wiring;
- Record the value stored inside the HARDWARE BATTERY RANGE
parameter in the SPECIAL ADJUST. list and contact a Zapi technician.
- In case the problem is not solved, replace the logic board.