Glossary
170
P1056468-002 7/3/13
symbology The term generally used when referring to a bar code.
tag A type of media having no adhesive backing but featuring a hole or notch by which the
tag can be hung on something. Tags are usually made of cardboard or other durable material.
tear-off A mode of operation in which the user tears the label or tag stock away from the
remaining media by hand.
thermal transfer A printing method in which the printhead presses an ink or resin coated
ribbon against the media. Heating the printhead elements causes the ink or resin to transfer
onto the media. By selectively heating the printhead elements as the media and ribbon move
past, an image is printed onto the media. Contrast this with direct thermal.
void A space on which printing should have occurred, but did not due to an error condition
such as wrinkled ribbon or faulty print elements. A void can cause a printed bar code symbol
to be read incorrectly or not at all.

Table of Contents

Other manuals for Zebra 105SL Plus

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Zebra 105SL Plus and is the answer not in the manual?

Zebra 105SL Plus Specifications

General IconGeneral
Weight50 lbs / 22.7 kg
Humidity20-85% non-condensing
Print MethodThermal Transfer
Resolution203 dpi (8 dots/mm)
Max Print Width4.09 inches / 104 mm
Max Print Speed12 inches per second / 305 mm per second
Memory16 MB SDRAM, 8 MB Flash
Media Width0.79 inches / 20 mm to 4.5 inches / 114 mm
Media Thickness0.003 inches / 0.076 mm to 0.012 inches / 0.305 mm
Media TypesContinuous, die-cut, black mark
Ribbon Width2.00 inches / 51 mm to 4.33 inches / 110 mm
Ribbon Length1476'/450 m
ConnectivityParallel, Serial
Optional ConnectivityEthernet, Wireless
Power Requirements90-264 VAC; 48-62 Hz
Operating Temperature40°F to 105°F / 5°C to 40°C
Storage Temperature-40°F to 140°F / -40°C to 60°C