7 - 12 LI2208 PRODUCT REFERENCE GUIDE
Aiming Illumination
Parameter # 1187
Scan a bar code below to select a preferred aiming pattern. When solid aiming pattern is selected, the scanner
LED is on steadily when aiming. When pulsing pattern is selected, a pulsing LED pattern displays when
aiming.
.
Low Power Mode
Parameter # 128
If enabled, the linear imager enters a low power consumption mode after Time Delay to Low Power Mode has
expired, in which the LEDs turn off in order to conserve energy and prolong the life of the scanner. The linear
imager wakes when it senses a trigger pull or when the host attempts to communicate.
If disabled, power remains on after each decode attempt.
NOTE Pulsing Pattern or Solid Pattern is only applicable in hands-free mode.
*Pulsing Pattern
(01h)
Solid Pattern
(00h)
NOTE If hands-free trigger mode is enabled, see Hands-Free (Presentation) Trigger Mode on page
7-10, the linear imager does not go into lower power mode when it is seated in the stand.
Disable Low Power Mode
(00h)
* Enable Low Power Mode
(01h)