Maintenance
Link Status
Parameter Description
Link Name/ID This matches the Link Name/ID parameter that is configured
during Link Configuration.
RoIP Local Transmit Active: IP Gateway is transmitting radio audio.
Idle: IP Gateway is not transmitting radio audio.
RoIP Local Receive Active: IP Gateway is receiving radio audio.
Idle: IP Gateway is not receiving radio audio.
RoIP SIP Transmit to… Active: This IP Gateway is transmitting RoIP SIP data to its
paired IP Gateway.
Idle: This IP Gateway is not transmitting RoIP SIP data.
RoIP SIP Receive on… Active: This IP Gateway is receiving RoIP SIP data from its
paired IP Gateway.
Idle: This IP Gateway is not receiving RoIP SIP data.
TCP Control Heartbeat… Indicates the connection status to the paired IP Gateway.
Last RTP received by… The amount of time passed since RTP was received from the
paired IP Gateway.
TCP Control Heartbeat
Connection Log
Click to view the TCP Command heartbeat connection log.
I/O Input State Indicates whether the I/O State is Active or Inactive. Whether the
active state is High or Low is defined in the Link settings (see
Link Configuration on page 39).
Logged Runtime A run counter showing the amount of time logged during
operation. Rebooting the unit or cycling its power will not cause
the runtime to reset.
Logged Reboots The number of power cycles and reboots since the log.txt file was
last deleted.
Option Installation
The Model 6300 IP Gateway uses licensing in order to determine the optional features
installed. Although the initial licensing occurs at the factory prior to delivery, additional
licensing can be installed in the field in order to support BSI links.