58 Installation and Operating Instructions V03
10.3 General data
General data
Zeverlution
1000S
Zeverlution
1500S
Zeverlution
2000S
Zeverlution
3000S
Communication
interfaces:
RS485 / RS485
1
) &
Ethernet & WIFI &
a.RJ45
2
)(DRED)
● / ○
Display
16 x 2 characters
Dimensions
(W x H x D)
346 x 346 x 132mm
346 x 346
x 146mm
Weight
6.5Kg
6.8Kg
Cooling concept
convection
Noise emission (typical)
< 15 dB(A)@1m
Installation
indoor & outdoor
Mounting information
wall mounting bracket
DC connection technology
SUNCLIX
AC connection technology
screw clamp terminal
Operating temperature
range
-25…+60 / -13…+140
Relative humidity
(non-condensing)
0% ... 100%
Max. operating altitude
4000m(>3000m derating)
Degree of protection
(according to IEC 60529)
IP65
Climatic category
(according to IEC
60721-3-4)
4K4H
Topology
H5
Self-consumption (night)
<1W
Standby power
<6W
Standard Optional -N/A
1) for 0-export with smart meter 2) only functional in AU & NZL