C2-260/inBio2-260 Access Control Panel
User Manual
Page | 22 Copyright©2020 ZKTECO CO., LTD. All rights reserved.
panels, respectively.
RS485 Communication System Networking
DIP Switch Settings 4.4
The Control panel adopts a rotary DIP switch. The numbers 1-4 of the DIP switch are set as the device
number for RS485 communication. The code is binary, and the numbering starts from left to right. When
the switch is set to ON position, it indicates 1 (ON); when the switch is set downwards, it means 0 (OFF).
For example, to set a device number as 15=1+2+4+8, which corresponds to the binary code 1111, move
the numbers 1, 2, 3, and 4 to ON position
.
Serial Line
PC
1# Control Panel
2# Control Panel
16# Control Panel