ZXR10 WAS (V1.0) W140A Outdoor Wireless Access Point / Bridge
Professional Installation Instruction Manual
2-10
version.
When you are sure that the APs work normally, you should proceed with the following
basic configurations:
1. Configuring IP addresses of the Ethernet interfaces, that is, the management
addresses. At least one management address should be configured for each AP
for the end of management configuration. This management address may be a
private address or a public address.
2. Configuring SSIDs and working channels of the wireless interfaces.
3. Configuring the working mode of the W140A.
The configuration methods will be elaborated in the subsequent sections.
2.2.3 Tools, Instruments and Documentations
1. Tools
A ladder, electric drill, wrench, diagonal pliers, scissors, 8-core cable clamp and
common toolkit.
2. Instrument
Multimeter
3. Documentations
W140A Installation Data Sheet
ZXR10 WAS (V1.0) IP Wireless Access System W140A Outdoor Wireless Access
Point / Bridge User’s Manual
2.2.4 Installation Environment Inspection
As the W140A is located outdoors, you should make sure that the lightning protection
measures are in place.
Generally, the W140A uses W201P as the PoE product, which must be located indoors.
To guarantee the normal work of the W201P and prolong its service lifetime, the indoor
temperature should be in the range of -5°C ~ 45°C, and the relative humidity in the
range of 5% ~ 95%. The equipment room should be dry and ventilated.