ZXR10 WAS (V1.0) W140A Outdoor Wireless Access Point / Bridge
Professional Installation Instruction Manual
2-16
Note:
● All the antennas must be clamped on the metallic casings, to ensure that all the
other parts in the antennas do not bear any weight.
● The antenna feeder shall go through the left and right locks of the W140A to make
it look nicer.
4. Installing the W140A: Securing the W140A with a backplane to the mounting
plane on the wall with reference to the three fastening holes in the backplane and
by using the fastening screws.
5. Fixing the antenna: Turn the antenna stand to place the antenna in an optimum
position. Then tighten the U-shape fixture to fix the antenna stand firmly.
6. Connecting the cable: Interconnect the U-interface cable led out from the
distribution box with the twisted pairs of the W140A, and carry out water-proof
and anti-aging treatment. Connect and tighten the cable connectors of the
antenna with the antenna interface of the W140A, and make sure that they are
waterproof.
2.3.2.3
Roof-Mounted Mode
The roof-mounted mode is suitable for installing an omni antenna or a directional
antenna. When the W140A is not within the 45° protection area of other lightning
arresters, a lightning arrester should be installed in an installing support A or C.
Fig. 2.3-5 shows the components in the roof-mounted mode with an installing support
C, and Fig. 2.3-6 shows the components in the roof-mounted mode with an installing
support A.