Chapter 4 The Web Configurator
XGS2210 Series User’s Guide
37
Change the default administrator and/or SNMP passwords, and then click Apply to save your changes.
4.3 The Status Screen
The Status screen is the first screen that displays when you access the web configurator.
This guide uses the XGS2210-52HP screens as an example. The screens may very slightly for different
models.
The following figure shows the navigating components of a web configurator screen.
Table 5 Web Configurator: Password/SNMP
LABEL DESCRIPTION
Administrator
This is the default administrator account with the “admin” user name. You cannot change the default administrator
user name. Only the administrator has read/write access.
Old Password Type the existing system password (1234 is the default password when shipped).
New Password Enter your new system password.
Retype to confirm Retype your new system password for confirmation
General Setting
Use this section to specify the SNMP version and community (password) values.
Version Select the SNMP version for the Switch. The SNMP version on the Switch must match the version
on the SNMP manager. Choose SNMP version 2c (v2c), SNMP version 3 (v3) or both (v3v2c).
Note: SNMP version 2c is backwards compatible with SNMP version 1.
Get Community Enter the Get Community string, which is the password for the incoming Get- and GetNext-
requests from the management station.
The Get Community string is only used by SNMP managers using SNMP version 2c or lower.
Set Community Enter the Set Community string, which is the password for the incoming Set- requests from the
management station.
The Set Community string is only used by SNMP managers using SNMP version 2c or lower.
Trap Community Enter the Trap Community string, which is the password sent with each trap to the SNMP
manager.
The Trap Community string is only used by SNMP managers using SNMP version 2c or lower.
Apply Click Apply to save your changes to the Switch’s run-time memory. The Switch loses these
changes if it is turned off or loses power, so use the Save link on the top navigation panel to
save your changes to the non-volatile memory when you are done configuring.
Cancel Click Cancel to begin configuring this screen afresh.