EasyManua.ls Logo

4RF Aprisa SR - Page 304

4RF Aprisa SR
327 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
302 | Alarm Types and Sources
Aprisa SRx User Manual 1.3.0
Event
ID
Event Display
Text
Default
Severity
Configuration
Type
Function
Recommended Actions
63
USB Port Serial
Data No Receive
Data
warning(4)
Sample Duration
Type
Alarm to indicate that the
USB port has no received
input signal in the defined
duration period.
Check serial ports settings,
check USB serial cable and
adapter, check serial
connector.
64
USB Port Serial
Data Receive
Errors
warning(4)
Error Ratio Type
Alarm to indicate that the
USB port received input
signal contains errors at a
higher rate than the defined
error rate threshold.
Check serial ports settings,
check USB serial cable and
adapter, check serial
connector.
Component Failure Alarm Events
Event
ID
Event Display
Text
Default
Severity
Configuration
Type
Function
Recommended Actions
16
Component
Failure
major(2)
Not Configurable
Alarm to indicate that a
hardware component has
failed.
Power off and restart radio.
If fault persists replace
radio.

Table of Contents