Covers warnings about electric shock, fire, and explosion risks.
Details mandatory grounding procedures for safe installation.
Outlines installation compliance with relevant building and electrical codes.
Instructions for checking the controller for damage upon receipt.
Guidelines for selecting an optimal location and physically mounting the controller.
Details requirements for control wire size to ensure proper operation and prevent voltage drop.
Instructions for connecting the controller to a BACnet MS/TP network.
Explains how to connect various input devices like sensors and switches.
Details how to connect devices to the controller's output terminals.
Explains button functions for menu interaction and navigating the interface.
Overview of the initial power-up and setup process for the controller.
How to configure settings and overrides directly from the home screen.
Details the different system modes like Auto, Cooling, Heating, and Off.
Lists and describes various alarm triggers for temperature, humidity, and fan status.
Defines key setpoints like cooling, heating, and setbacks for occupied/unoccupied modes.
Configuration of the controller's date and time parameters.
Steps for setting up weekly schedules and holidays.
Configuration of advanced temperature and humidity setpoints and deadbands.
Configuration of system enable, overrides, inactivity timers, and display options.
Functionality for viewing logged operational data.
Used for configuring the controller's application type, stages, and SAT control.
Configuration options for economizer damper, enthalpy, and temperature limits.
Configuration of fan speeds, off delay, and maximum cooling speed.
Detailed settings for fan speeds in various modes (cool, heat, dehumidification).
Configuration of dehumidification mode, priority, setpoints, and deadbands.
Configuration options for external sensors like OAT, SAT, and AI2 inputs.
Configuration for compressor stage delay and heat pump reversing valve.
Settings for MAC address, baud rate, max master, and BACnet device configuration.
Settings for date, time, UTC offset, and controller restart modes.
Configuration of limits for occupied/unoccupied temperatures and outside/supply air.
Settings for compressor capacity and minimum on/off times.
Allows setting user, operator, and administrator access levels and passwords.
Configuration for trend logs and testing controller functions.
Table detailing default access permissions for User, Operator, and Administrator.
Steps for configuring the unit application, stages, and sensors.
Steps for configuring fan speeds and supply air temperature control.
Verifying limit values within the controller settings.
Steps for configuring a VAV system with cooling and constant volume heating.
Verifying setpoints and checking date/time settings.
Steps for setting up weekly schedules and holidays.
Steps for configuring a VAV system with cooling and variable volume heating.
Verifying setpoints and checking date/time settings.
Steps for setting up weekly schedules and holidays.
Steps for configuring a VAV heat pump with cooling and constant volume heating.
Verifying setpoints and checking date/time settings.
Steps for setting up weekly schedules and holidays.
Configuring the heat pump application, compressor stages, and emergency heat.
Setting up OAT/SAT sensors and supply air temperature control.
Configuring reversing valve active mode and fan speeds.
Steps for configuring a VAV heat pump with cooling and constant volume heating.
Verifying setpoints and checking date/time settings.
Steps for setting up weekly schedules and holidays.
Steps for configuring a VAV heat pump with cooling and variable volume heating.
Verifying setpoints and checking date/time settings.
Steps for setting up weekly schedules and holidays.
Steps for configuring a VAV heat pump with cooling and variable volume heating.
Verifying setpoints and limit values.
Steps for configuring sensors and humidity parameters for hot gas reheat.
Configuring economizer sensors, damper, and settings.
Configuring CO2 override and remote sensors for temperature control.
Configuring the sensor for fan status monitoring.
Describes operation of single/two-stage cooling with variable capacity compressors.
Explains how the controller manages cooling for constant volume systems.
Details cooling operation for VAV systems, including supply air temperature control.
Explains heating control for constant volume systems based on space temperature.
Details heating operation for VAV systems, including supply air temperature control.
Explains heating control for heat pumps based on space temperature.
Details heating operation for VAV heat pumps, including emergency heating.
Configuration and operation of constant volume supply fans.
Details supply fan operation for VAV systems based on space temperature.
Explains economizer control logic based on temperature, enthalpy, and setpoints.
Describes dehumidification logic, priority, and hot gas reheat.
Configuring CO2 override and remote sensors for temperature control.
Lists and defines analog input/output objects and their default/range values.
Continues the list of analog input/output objects and their parameters.
Lists and defines binary output objects (relays) and their functions.
Defines multi-state objects for application and mode settings.
Lists and defines analog input objects.
Lists and defines analog output objects.
Lists and defines relay output objects.
Outlines recommended annual and monthly service checks for the unit.
Information on how to obtain replacement parts from AAON.
Provides definitions for technical terms and acronyms used in the manual.
Continues the definitions of technical terms and parameters.
Further definitions of technical terms and parameters.
Checklist for contractors to verify before initial controller startup.
Selections for configuring the unit type and supply fan control.