Ascotel® IntelliGate® 150/300 as of I7.9
Operation and Maintenance 195
syd-0210/1.7 – I7.9 – 12.2009
Sync. lost on trunk re-estab-
lished
A T / T2 interface entered in the clock pool has
been successfully re-synchronized with the
system clock.
Port number, date, time
Sync. lost re-established Synchronization with the network has been
restored on at least one T / T2 interface.
Date, time
Synchronisation loss to
exchange
A T / T2 interface entered in the clock pool has
lost the system clock.
Port number, date, time
System overload Network access attempted when all lines are
seized or the PBX is overloaded.
Route number, user number,
date, time
The System has crashed The System has crashed Date, time
Too few FoIP channels Setting up a fax connection via T.38 failed
because no FoIP channel is available.
Available FoIP channels on
nodes
Too few licences for GSM ter-
minals
The connection setup with an integrated GSM
terminal failed because the number of config-
ured GSM terminals is greater than the
number of licences for GSM terminals. All the
integrated GSM terminals remain blocked
until there are enough GSM licences.
Number of GSM licences,
number of configured GSM ter-
minals, date, time
Too few licences for IP system
terminals
An Aastra 5360ip/5370ip/5380ip was unable
to register because there are too few IP system
terminal licences.
Date, time
Too few VoIP channel
licences
Connection setup failed because the licence
limit for simultaneously active VoIP channels
has been reached.
No. of licensed VoIP channels,
Date, Time
Too few VoIP channels An user is trying to set up a connection that
requires one or more VoIP channels which are
currently not available.
Available VoIP channels on this
node, date, time
Too many event messages Number of message types exceeds limit
entered in the table on:
"Sync. Loss on T / T2"
"Outgoing Call Rejected"
"No response from network"
Date, time
Too many network interfaces System limits exceeded Card No., date, time
Too much user data System limits exceeded Date, time
Total Synchronization loss Synchronization with network has failed on all
T / T2 interfaces
Date, time
Trial licence expired The duration for which a trial licence can be
used for a specific feature has expired and
there is no valid licence.
Licence ID, date, time
User alarm With *77[nnnn] from a terminal nnnn [0000...99999], user
number, date, time
Event/ error message Trigger condition Details