204 Operation and Maintenance
syd-0210/1.7 – I7.9 – 12.2009
PC format
The event signal format "PC" is required if a PC is configured as the local signal des-
tination using the System Event Manager (SEM).
Configuring a local signal destination on an S interface / ISDN
As with an external signal destination the event message opens a PPP communica-
tion channel from the PBX to a Terminal Adapter, connected either directly to a PC
with the System Event Manager (SEM) or indirectly via a LAN (ISDN gateway). Once
the event has been confirmed, the PBX clears down the PPP connection.
Configuring a local signal destination on an S interface
The event messages are displayed in PC format.
The "Local Output Interface" must be set on "IP Destination" in the Fault & Mainte-
nance Manager.
The following parameters need to be selected or entered in the Fault & Mainte-
nance Manager:
Destination: “Local PPP” communication protocol.
Call number of the local signal destination (the call number is checked by the
PBX, a warning message will appear if the call number is incorrect)
IP address of the PC if the PBX is to connect with the PC via an ISDN gateway.
If the PBX is to connect with the PC without ISDN gateway, the "IP address" entry
should remain empty.
TCP port number (the initialization value is 1062; if the value is changed in the
SEM, it will have to be altered accordingly on the PBX side.)
User name and password of the dial-up networking of the PC or ISDN gateway,
to gain access via the TA or the ISDN gateway to the PC with the SEM.
Configuring a local signal destination on ISDN
The event messages are displayed in PC format.
The "Local Output Interface" must be set on "IP Destination" in the Fault & Mainte-
nance Manager.
The following parameters need to be selected or entered in the Fault & Mainte-
nance Manager:
Destination: PPP via ISDN communication protocol