Operation and Maintenance 203
syd-0210/1.7 – I7.9 – 12.2009
Note:
Event tables and signal destinations should be set in such a way that the
event message Internal event message destination missing" is signalled
immediately to any signal destination still available.
Configuring a local signal destination on a V.24 interface
The local signal destination is connected to the V.24 interface of a Pocket Adapter
(PA).
The "Local Output Interface" must be set on "Printer" in the Fault & Maintenance
Manager.
The following parameters need to be selected or entered in the Fault & Mainte-
nance Manager:
• Location of the V.24 interface to which the local output destination is connected
(V.24 PA = Pocket Adapter)
• Required output format "PC" or "Printer" (see "Output formats", page 203)
• With "Printer" output format: Language in which the event messages are to be
output.
• With the V.24 interface on the PA - port address
• With "PC" and “Printer” output format as the output location: Maximum page
length of the printout
Output formats
There are two output formats available for local signal destinations connected to a
V.24 interface.
• Printer Format
• PC format
Printer Format
Fig. 81 Event signal format "Printer" for printer as the local output destination (example with date,
time and event message)
11.03.97 10:12 LOSS OF SYNC ON T/T2 O.9
haz1234aaena0
11.03.97 10:12 LOSS OF SYNC ON T/T2 O.9
haz1234aaena0