EasyManua.ls Logo

ABB AC500-S - 7.2.2 Graphical overview of safety application interface; 7.2.3 Declaration of used variables

ABB AC500-S
452 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
7.2.2 Graphical overview of safety application interface
Safety Application
S1_S_EStopIn_1
Functional Application
Standard
Outputs
S1
DiagCodes
Errors
S_Stopped
S0
S1_S_EStopIn_2
S3
Emergency
Stop
S0_Reset
EStop
Reset
Safety
Input
Standard
Input
S3_Drive_Reset
Drive Error
Ackonwledge
S0_Reset
All DiagCodes
& All Errors
Visualization
Safety Drive
Axis 1
Safety
Input
SF_SafeStop1_ 1
Safety
Inputs
S2
S2_S_ESPE_In
Light
Curtain
Standard
Inputs
Fig. 134: Graphical overview of the example with emergency stop
The symbol represents a direct opening action
(
Ä
IEC 60947-5-1).
7.2.3 Declaration of used variables
Table 90: Inputs
Name Data type Description
S1_S_EstopIn_1 BOOL Emergency Stop Channel 1
S1_S_EstopIn_2 BOOL Emergency Stop Channel 2
S2_ESPE_In BOOL Light curtain signal
S0_Reset BOOL Reset Emergency Stop and ESPE
S3_Drive_Reset BOOL Reset Drive Error
Table 91: Outputs
Name Data type Description
S_Stopped BOOL Indication of Safe Stop of drive
All Errors BOOL Errors of SF_Function Blocks
All Diagcodes BOOL Diag codes of SF_Function Blocks
Safety application examples
Example 1: Diagnostics concept > Declaration of used variables
30.03.2017 AC500-S 427

Table of Contents

Other manuals for ABB AC500-S

Related product manuals