EasyManua.ls Logo

ABB AC500-S - 7.4.2 Graphical overview of the safety application interface; 7.4.3 Declaration of used variables

ABB AC500-S
452 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
7.4.2 Graphical overview of the safety application interface
The safety inputs for the two-hand control (S2_S_Switch1 and S3_S_Switch2) are connected to the two-
hand control type II.
Safety
Input
Safety Application
S1_S_EStopIn
Functional Application
Standard
Input
Standard
Outputs
S1
S_EDM_Out_EDM_K1_K2
S2_S_Switch1
S3_S_Switch2
S0_Reset
Process
All DiagCodes
All Errors
Safety
Output
Safety
Input
S2
Safety
Input
S3
K1 K2
Safety
Input
K1
Safety
Input
K2
K1_S_EDM1
K2_S_EDM2
S0
Emerge ncy
Stop
Pushbutton 1
Pushbutton 2
Feedback K1
Feedback K2
User
Re set
Fig. 139: Graphical overview of the example TwoHand Control with EDM
7.4.3 Declaration of used variables
Table 97: Inputs
Name Data type Description
S1_S_EStopIn BOOL Emergency stop button S1
S2_S_Switch1 BOOL Switch S2 related to push button 1 of two hand control
Safety application examples
Example 3: Two-hand control > Declaration of used variables
30.03.2017AC500-S438