11 PREVENTIVE AND CORRECTIVE MAINTENANCE
3BHS213401 E01 REV H ACS1000 AIR-COOLED USER MANUAL 173/184
11.6.10.2 Replacing a battery
CAUTION
Figure 11-7: Control compartment - replacing the batteries
1. When the drive is in operation, disable the battery monitoring function first. To do this, set
parameter 31.05 DISABLE BATTERY TEST
to ON.
Note: Parameter 31.05 is automatically set to OFF after 1 hour.
2. Disconnect the wires (1 in Fig. 11-7).
3. Unscrew the battery at the front (2 in Fig. 11-7) and at the back (3 in Fig. 11-7).Install the new
battery in reverse order of removal.
4. Record the date of battery replacement in the logbook
~10 kg
Each battery weighs approximately 10 kg!