Parameters 133
Const Bit pointer setting (see Terms and abbreviations on page 93). -
Pointer
14.34 DIO9 conf Selects whether DIO9 is used as a digital output or input.
Output DIO9 is used as a digital output. 0
Input DIO9 is used as a digital input. 1
14.35 DIO9 out src Selects a drive signal to be connected to digital output DIO9
(when 14.34 DIO9 conf is set to Output).
Brake cmd 03.16 Brake command (see page 101). 1073742608
Ready Bit 0 of 06.01 Status word1 (see page 103). 1073743361
Enabled Bit 1 of 06.01 Status word1 (see page 103). 1073808897
Started Bit 2 of 06.01 Status word1 (see page 103). 1073874433
Running Bit 3 of 06.01 Status word1 (see page 103). 1073939969
Alarm Bit 7 of 06.01 Status word1 (see page 103). 1074202113
Ext2 active Bit 8 of 06.01 Status word1 (see page 103). 1074267649
Fault Bit 10 of 06.01 Status word1 (see page 103). 1074398721
Fault(-1) Bit 12 of 06.01 Status word1 (see page 103). 1074529793
Ready relay Bit 2 of 06.02 Status word2 (see page 104). 1073874434
RunningRelay Bit 3 of 06.02 Status word2 (see page 104). 1073939970
Ref running Bit 4 of 06.02 Status word2 (see page 104). 1074005506
Charge ready Bit 9 of 06.02 Status word2 (see page 104). 1074333186
Neg speed Bit 0 of 06.03 Speed ctrl stat (see page 105). 1073743363
Zero speed Bit 1 of 06.03 Speed ctrl stat (see page 105). 1073808899
Above limit Bit 2 of 06.03 Speed ctrl stat (see page 105). 1073874435
At setpoint Bit 3 of 06.03 Speed ctrl stat (see page 105). 1073939971
Supervision1 Bit 0 of 06.13 Superv status (see page 106). 1073743373
Supervision2 Bit 1 of 06.13 Superv status (see page 106). 1073808909
Supervision3 Bit 2 of 06.13 Superv status (see page 106). 1073874445
Const Bit pointer setting (see Terms and abbreviations on page 93). -
Pointer
14.38 DIO10 conf Selects whether DIO10 is used as a digital output or input.
Output DIO10 is used as a digital output. 0
Input DIO10 is used as a digital input. 1
14.39 DIO10 out src Selects a drive signal to be connected to digital output DIO10
(when 14.38 DIO10 conf is set to Output).
Brake cmd 03.16 Brake command (see page 101). 1073742608
Ready Bit 0 of 06.01 Status word1 (see page 103). 1073743361
Enabled Bit 1 of 06.01 Status word1 (see page 103). 1073808897
Started Bit 2 of 06.01 Status word1 (see page 103). 1073874433
Running Bit 3 of 06.01 Status word1 (see page 103). 1073939969
Alarm Bit 7 of 06.01 Status word1 (see page 103). 1074202113
Ext2 active Bit 8 of 06.01 Status word1 (see page 103). 1074267649
Fault Bit 10 of 06.01 Status word1 (see page 103). 1074398721