EasyManua.ls Logo

ABB ACS880-01-061A-3+N5350 - Page 196

ABB ACS880-01-061A-3+N5350
247 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Technical Specications A-33AXD50000011888
Analog Outputs
AO1 and AO2
(XAO)
Connector pitch 5mm, wire size 2.5mm
2
0…20mA, R
load
< 500ohm
Frequency range: 0…300Hz
Resolution: 11 bit + sign bit
Inaccuracy: 2% of full scale range
Drive to Drive Link
(XD2D)
Connector pitch 5mm, wire size 2.5mm
2
Physical layer: RS-485
Termination by switch
Safe Torque Off
Connection (XSTO)
Connector pitch 5mm, wire size 2.5mm
2
Current consumption per channel: 55mA (continuous)
For the drive to start, both connections must be closed (OUT1 to IN1 and IN2).
Control Panel / PC
Connection
Connector: RJ-45
Cable length < 3m
The terminals on the board full the Protective Extra Low Voltage (PELV) requirements. The PELV requirements of a relay
output are not fullled if a voltage higher than 48V is connected to the relay output.
Table A-1 ACS880+N5350 Technical Data Continued

Table of Contents

Related product manuals