Advant
®
OCS
with Master
software
Advant Cont
roller 450
V
ersion 2.3/1
Product Guide
3BSE 0
15 953R201
Rev B
2
Table of Contents
default chapter
3
Table of Contents
3
Chapter 1 Overview
13
Product Benefits
13
Figure 1-1. Advant Controller 450 with S100 I/O
13
Features
14
Chapter 2 Functional Description
15
General Controller Utilities
15
Cpu
15
Memory and Backup
15
System Clock, External Clock Synchronization
16
Configuration
17
Execution
17
Start-Up
17
Process Control
17
I/O System Support
19
Time Tagging of Events and Alarms
19
Pulse Counting and Positioning
20
Switchgear Integration
20
Figure 2-1. AC 400 Series Configuration with INSUM Motor Controller
20
Drives Integration
21
Variable Speed Drive Control
21
Communication
21
Advacommand Support
22
Local Operator Station Masterview 320
23
Local Printer
24
Scope of Controller Functions
24
Table 2-2. Functions and Configuration Alternatives for Advant Controller 450
25
Chapter 3 Software Components
29
Basic Program Module, QC07-BAS41
29
Table 3-1. PC Elements in the Basic Program Module QC07-BAS41
30
Table 3-2. Functional Units in the Base Program Module QC07-BAS41
31
Optional Program Module, QC07-LIB41
32
Table 3-3. Additional PC Elements in Program Module QC07-LIB41
32
Optional Program Module, QC07-LIB42
33
Table 3-4. Additional PC Elements in Program Module QC07-LIB42
33
Table 3-5. Functional Units in the Program Module QC07-LIB42
33
Optional Program Module QC07-FUZ41
34
Optional Program Module, QC07-OPF41
34
Optional Program Module, QC07-LOS41
34
Table 3-6. Additional PC Element in Program Module QC07-FUZ41
34
Optional Program Module, QC07-BAT41
35
Optional Program Module, QC07-UDP41
35
Optional Program Module, QC07-COM41
35
Table 3-7. Additional PC Elements in Program Module QC07-COM41
35
Chapter 4 Hardware Components
37
Processor Module
37
Figure 4-1. Front View of the Processor Module PM511V
37
Program Card
38
Submodule Carriers
38
Submodules
39
Table 4-1. Submodules
39
Subrack
40
System Unit
41
I/O Systems
41
Table 4-2. System Unit for Advant Controller 450
41
Table 4-3. S100 I/O Bus Extensions
41
Communication
42
Control Network
42
Fieldbus Communication
42
Figure 4-5. Advant Fieldbus 100 Using Twisted Pair Media Connected to
43
Figure 4-6. Advant Fieldbus 100 Using Media Redundancy Connected to
43
Figure 4-7. Advant Fieldbus 100 Using Bus Redundancy Connected to Advant Controller 450
44
External Communication
46
Telecontrol & SPA Bus
47
Power Supply System
48
Mains Network Types
48
Redundancy, Mains Power Supply
48
Configuration Alternatives
49
Figure 4-16. Block Diagram of Power Supply Solution Without Redundancy
49
Figure 4-17. Configuration Examples of Redundant Power Supplies
50
ESD Protection
51
CE Marked Equipment
51
Chapter 5 Mechanical Design
53
Cabinet Design
53
Figure 5-1. Typical Advant Controller 450 with S100 I/O
53
Product Design
54
Figure 5-2. Maximum Cabinet Configuration for Advant Controller 450 with S100 I/O Assembled in RM500V1 Cabinets
55
Table 5-1. RM500V1 Configurations for Advant Controller 450 with S100 I/O
55
Figure 5-3. Maximum Cabinet Configuration for Advant Controller 450 with S100 I/O Assembled in RM500V2 Cabinets
56
Table 5-2. RM500V2 Configurations for Advant Controller 450 with S100 I/O
57
Chapter 6 Technical Data and Performance
59
PC Program
59
I/O Signals
59
I/O Boards
60
Connection Unit Dimensions
61
Table 6-3. the Width of the Connection Units
61
Functional Units
62
Communication
63
Data Set and Text Set
63
Data Set Peripheral (DSP)
63
Communication Buses
64
Table 6-6. Submodules Mounted in Submodule Carriers
64
Time Synchronization
66
Time Tagging of Events (Alarms)
66
Trend Data Storage
67
Table 6-7. Relative Time Errors between Events (DI Signals)
67
Table 6-8. Data Logging Capabilities
67
CPU Load Calculation
68
Table 6-9. Execution Times
68
Table 6-10. Examples of CPU Load
69
CPU Load from Data Set Communication
70
CPU Load from Data Set Peripheral Communication
70
Table 6-11. CPU Load with Masterbus 300 Executed in Main CPU
70
Table 6-12. CPU Load with Masterbus 300 Executed in Slave CPU (SC520)
70
Table 6-13. the CPU Load Caused by Data Set Peripheral Communication (Cycle Time of Scan Task = 512 Ms)
70
Read/Write Memory (RAM) Requirements
71
Table 6-14. Calculation of RAM Requirement
71
Program Module Size on Program Card
73
Table 6-15. Program Module Memory Area on Program Card
73
Controller Subrack
74
Figure 6-1. the Division of the Controller Subrack
74
Table 6-16. the No. of Slots in the Controller Subrack
74
Table 6-17. Modules that Can Go into Part a of the Controller Subrack
74
Table 6-18. Modules Placed in Part B and C of the Controller Subrack
74
Cabinet RM500
75
Mounting Bars for Connection Units
75
Table 6-19. RM500 Cabinets Dimensions
75
Table 6-20. RM500 Cabinet Protection Classes
75
Chapter 7 Environmental Immunities
77
Environmental Considerations
77
Chapter 8 Ordering Price List Structure
79
Basic Software Licenses
80
Assembled Delivery or Loose Part Delivery
80
Loose Part Delivery and CE-Marking
81
Non Standard Program Modules
81
Heat Exchanger
81
Reference Guide
81
General Requirements
82
System Units
82
Table 8-1. General and Normative Requirements
82
Software Licenses
83
Software Options
83
Special Applications
84
System Software Back-Up Card
85
Items for Accuray QCS
85
Hardware Options
86
Communication
87
Printers
92
Power Supply System
93
Other manuals for ABB Advant Controller 450
User Guide
564 pages
5
Based on 1 rating
Ask a question
Give review
Questions and Answers:
Need help?
Do you have a question about the ABB Advant Controller 450 and is the answer not in the manual?
Ask a question
ABB Advant Controller 450 Specifications
General
Power Supply
24 V DC
Communication Ports
Ethernet
Programming Languages
IEC 61131-3
I/O Modules
Digital, Analog
Certifications
CE, UL
Related product manuals
ABB Advant Controller 80
84 pages
ABB AC500
18 pages
ABB ACS550
310 pages
ABB ACS320
442 pages
ABB ACQ580
5 pages
ABB ACS150
156 pages
ABB AC 800M
230 pages
ABB ACH 400
48 pages
ABB ACH 500
117 pages
ABB AC 900F
156 pages
ABB ACS 601
88 pages
ABB ACS 400
187 pages