12.4 Torque specifications
Parameter Specification
[Nm] [ft-lbs]
Nuts on PE busbar 30 22
Nuts on the AC power busbars 30 22
Screws in the terminal blocks (X1, X2, X3,
X5, X6, X7
, X8)
1,3 0.9
Nuts on the DC power busbars 30 22
M5 fasteners (if not specified otherwise) 3,5 2.6
M6 fasteners (if not specified otherwise) 9 6.6
M8 fasteners (if not specified otherwise) 20 15
M10 fasteners (if not specified other-
wise)
40 29
M12 fasteners (if not specified other-
wise)
70 51
M16 fasteners (if not specified other-
wise)
180 132
M16 cable glands 2 1.4
M20 cable glands 4,5 3.3
M25 cable glands 5 3.6
M32 cable glands 6 4.4
M40 cable glands 10 7.3
12.5 General specifications
Parameter Specification
Compliance and safety UL 2202:2009 R2.18
CSA STD C22.2 No 107.1-16
FCC Part 15 Class A
IP rating IP54
IK rating according to IEC 62262: enclo-
sur
e
IK10
Short circuit current rating 65 kA
Electro Magnetic Compatibility (EMC)
rating
FCC Directive Immunity: Class A
Emissions: Class A
12.6 Cleaning specifications
Parameter Specification
Cleaning agent pH value between 6 and 8
Non-abrasive tool Non-woven nylon hand pad