12.15 DC output specifications
12.15.1 DC output specifications
Parameter Specification
Power variant [kW] 200 300 360
Max output voltage [V DC] 940 940 940
Maximum
output cur-
rent per one
outlet [A]
Static 2 outlets
• 142 A at
700 V DC
• 125 A at
800 V DC
• 215 A at
700V DC
• 188 A at
800 V DC
• 250 A at
700 V DC
• 225 A at
800 V DC
4 outlets
• 71A at
700 V DC
• 63 A at
800 V DC
• 105 A at
700 V DC
• 90 A at
800 V DC
• 125 A at
720 V DC
• 125 A at
800 V DC
Dynamic 2 outlets
• 285 A at
700 V DC
• 250 A at
800 V DC
• 430 A at
700 V DC
• 375 A at
800 V DC
• 500 A at
720 V DC
• 450 A at
800 V DC
4 outlets
• 285 A at
700 V DC
• 250 A at
800 V DC
• 430 A at
700 V DC
• 375 A at
800 V DC
• 500 A at
720 V DC
• 450 A at
800 V DC
Maximum
output cur-
rent in total
for the
whole charg-
er [A]
Static 2 outlets
• 285 A at
700 V DC
• 250 A at
800 V DC
• 430 A at
700 V DC
• 375 A at
800 V DC
• 500 A at
720 V DC
• 450 A at
800 V DC
4 outlets
• 285 A at
700 V DC
• 250 A at
800 V DC
• 430 A at
700 V DC
• 375 A at
800 V DC
• 500 A at
720 V DC
• 450 A at
800 V DC
Dynamic 2 outlets
• 285 A at
700 V DC
• 250 A at
800 V DC
• 430 A at
700 V DC
• 375 A at
800 V DC
• 500 A at
720 V DC
• 450 A at
800 V DC
4 outlets
• 285 A at
700 V DC
• 250 A at
800 V DC
• 430 A at
700 V DC
• 375 A at
800 V DC
• 500 A at
720 V DC
• 450 A at
800 V DC
Technical data
88 HVC 200/300/360-EN | 002