1.3.2 Mounting the manipulator
Maximum load
Maximum load in relation to the base coordination system. See Figure below.
Floor Mounted
Max. load (emergency stop)Endurance load (in operation)Force
±515 N±265 NForce xy
-265 ±365 N-265 ±200 NForce z
±400 Nm±195 NmTorque xy
±155 Nm±85 NmTorque z
Wall Mounted
Max. load (emergency stop)Endurance load (in operation)Force
±735 N±470 NForce xy
0 ±630 N0 ±200 NForce z
±450 Nm±240 NmTorque xy
±175 Nm±90 NmTorque z
Suspended
Max. load (emergency stop)Endurance load (in operation)Force
±515 N±265 NForce xy
265 ±365 N265 ±200 NForce z
±400 Nm±195 NmTorque xy
±155 Nm±85 NmTorque z
Continues on next page
Product specification - IRB 120 17
3HAC035960-001 Revision: T