NoteAction
DANGER
There is stored energy built up by high
tensioned compression springs inside the
balancing device! When a coil is cut the
released tension creates a spatter of
sparks and flames.
The working area must be free of flam-
mable materials. Position the balancing
device so that the spatter will be directed
away from personnel.
6
Use a cutting torch with a long shaft.Cut at least eight coils of the spring inside
the housing.
7
Double-check the number of coils cut and
make sure all the tension in the spring is
removed.
8
Cut more coils if there is still tension in the
spring.
338 Product manual - IRB 660
3HAC025755-001 Revision: W
© Copyright 2006-2020 ABB. All rights reserved.
6 Decommissioning
6.3 Decommissioning of balancing device
Continued

Table of Contents