136  FEP630, FEH630 ELECTROMAGNETIC FLOWMETER  |  OI/FEP630/FEH630-EN REV. D   
   
… 13 Specification 
ProcessMaster – Material load for process connections 
 
 
The limits of the permissible measuring medium temperature 
(T
medium
) and permissible pressure (P
medium
) are calculated on 
the basis of the liner and flange material used in the device (see 
device name plate). 
 
 
Minimum permissible operating pressure 
 
The following tables show the permissible minimum operating 
pressure (P
medium
) as a function of the measuring medium 
temperature (T
medium
) and the liner material. 
 
Design Level ‘A’ 
Lining material  Nominal diameter P
medium
[mbar abs]
T
medium
*
Hard rubber  DN 25 to DN 2000
(1 to 80 in)
0 < 85 °C (185 °F)
< 80 °C (176 °F)**
Soft rubber  DN 50 to DN 2000
(2 to 80 in)
0 < 60 °C (140 °F)
PTFE  DN 10 to DN 600
(⅜ to 24 in)
270 < 20 °C (68 °F)
400 < 100 °C (212 °F)
500 < 130 °C (266 °F)
Thick PTFE  DN 25 to DN 80
(1 to 3 in)
0 < 180 °C (356 °F)
  DN 100 to DN 250
(4 to 10 in)
67 < 180 °C (356 °F)
  DN 300 (12 in) 27 < 180 °C (356 °F)
PFA  DN 3 to DN 200
(¹⁄₁₀ to 8 in)
0 < 180 °C (356 °F)
ETFE  DN 25 to DN 600
(1 to 24 in)
100 < 130 °C (266 °F)
Ceramic carbide  DN 25 to DN 1000
(1 to 40 in)
0 < 80 °C (176 °F)
Linatex**  DN 50 to DN 600
(6 to 24 in)
0 < 70 °C (158 °F)
*  For CIP/SIP cleaning, higher temperatures are permitted for limited time 
periods; refer to Maximum permissible cleaning temperature on page 131. 
**  Only for China production site 
 
 
Design level ‘B’ 
Lining material  Nominal
diameter
P
medium
[mbar abs]
T
medium
*
PTFE  DN 25 to DN 300
(1 to 12 in)
270
< 20 °C (68 °F)
400
< 100 °C (212 °F)
500
< 130 °C (266 °F)
*  For CIP/SIP cleaning, higher temperatures are permitted for limited time 
periods; refer to Maximum permissible cleaning temperature on page 131. 
 