FEP630, FEH630 ELECTROMAGNETIC FLOWMETER  |  OI/FEP630/FEH630-EN REV. D  61 
 
8  Operation 
Safety instructions 
 
 CAUTION 
Risk of burns due to hot measuring media 
The device surface temperature may exceed 70 °C (158 °F), 
depending on the measuring medium temperature! 
•  Before starting work on the device, make sure that it has 
cooled sufficiently. 
 
 
Aggressive or corrosive media may lead to the damage of 
wetted parts of the sensor. As a result, measuring medium under 
pressure can leak out. 
Wear to the flange gasket or process connection gaskets 
(e.g. pipe fitting, Tri-clamp, etc.) may caused a pressurized 
measuring medium to escape. 
When using internal flat gaskets, they can become brittle 
through CIP- / SIP processes. 
If pressure surges above the permissible nominal pressure of the 
device occur permanently during operation, this may affect the 
service life of the device. 
 
 
If there is a chance that safe operation is no longer possible, 
take the device out of operation and secure it against 
unintended startup. 
 
 
Menu navigation 
 
M10145-01
1
 
2
 
Menu 
3 
 
4 
 
 
 
 
 
Exit  Select
1  Operating buttons for menu 
navigation 
2  Menu name display 
3  Menu number display 
4  Marker for indicating relative 
position within the menu  
5  Display showing the current 
functions of the   and   
operating buttons 
Figure 74:  LCD display 
 
 
 
 
 
The LCD indicator has capacitive operating buttons. These 
enable you to control the device through the closed housing 
cover. 
 
Note 
The transmitter automatically calibrates the capacitive buttons 
on a regular basis. If the cover is opened during operation, the 
sensitivity of the buttons is firstly increased to enable operating 
errors to occur. The button sensitivity will return to normal 
during the next automatic calibration. 
 
 
You can use the   or   operating buttons to browse through 
the menu or select a number or character within a parameter 
value. 
Different functions can be assigned to the   and   operating 
buttons. The function 
5 that is currently assigned to them is 
shown on the LCD display. 
 
Control button functions 
 
 Meaning 
Exit Exit menu 
Back  Go back one submenu 
Cancel  Cancel a parameter entry 
Next  Select the next position for entering numerical and 
alphanumeric values 
 
 Meaning 
Select  Select submenu / parameter 
Edit Edit parameter 
OK  Save parameter entered 
 
 
Change from two to one  column