Safety
CI/FEX300/FEX500-EN FEX300, FEX500 EN - 7
1.5 Plates and symbols
1.5.1 Safety- / warning symbols, note symbols
DANGER – <Serious damage to health / risk to life>
This symbol in conjunction with the signal word "Danger" indicates an imminent danger.
Failure to observe this safety information will result in death or severe injury.
DANGER – <Serious damage to health / risk to life>
This symbol in conjunction with the signal word "Danger" indicates an imminent electrical
hazard. Failure to observe this safety information will result in death or severe injury.
WARNING – <Bodily injury>
This symbol in conjunction with the signal word “Warning“ indicates a possibly dangerous
situation. Failure to observe this safety information may result in death or severe injury.
WARNING – <Bodily injury>
This symbol in conjunction with the signal word "Warning" indicates a potential electrical
hazard. Failure to observe this safety information may result in death or severe injury.
CAUTION – <Minor injury>
This symbol in conjunction with the signal word “Caution“ indicates a possibly dangerous
situation. Failure to observe this safety information may result in minor or moderate injury.
This may also be used for property damage warnings.
NOTICE – <Property damage>!
The symbol indicates a potentially damaging situation.
Failure to observe this safety information may result in damage to or destruction of the product
and/or other system components.
IMPORTANT (NOTE)
This symbol indicates operator tips, particularly useful information, or important information
about the product or its further uses. It does not indicate a dangerous or damaging situation.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ABB ProcessMaster and is the answer not in the manual?

ABB ProcessMaster Specifications

General IconGeneral
TypeElectromagnetic Flowmeter
Liner MaterialPTFE, PFA, Polyurethane, Rubber
Electrode MaterialStainless steel, Hastelloy, Tantalum, Titanium, Platinum
Process ConnectionFlange, Wafer
Fluid Temperature-40 to 180 °C (-40 to 356 °F) Depending on liner
Output4-20 mA, HART, PROFIBUS PA, FOUNDATION Fieldbus
Power Supply100 to 230 V AC, 24 V AC/DC
Protection ClassIP67
ApprovalsATEX, IECEx, FM, CSA