EasyManua.ls Logo

Abicor Binzel MIG - Removal from Service; Maintenance and Cleaning

Abicor Binzel MIG
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
EN - 17
MT/AUT/AUT RAB 8 Removal from service
8Removal from service
1 Welding is stopped.
2 Wait until the shielding gas flow has subsided.
3 Switch off power supply.
4 Close the valve of the shielding gas cylinder.
9 Maintenance and cleaning
NOTE
Liquid-cooled hose assemblies may start leaking if overheated. This is
why the cooling unit should continue running for approx. 5 min. after
welding.
DANGER
Risk of injury due to unexpected start-up.
For the entire duration of maintenance, servicing, dismounting and repair
work, the following instructions must be adhered to:
Switch off the power supply.
Cut off the gas supply.
Pull the mains plug.
DANGER
Electric shock
Dangerous voltage due to defective cables.
Check all live cables and connections for proper installation.
Replace any damaged, deformed or worn parts.
NOTE
The maintenance intervals given are recommended values and refer to
single-shift operation.
Maintenance and cleaning work may only be carried out by qualified
and trained specialists.
Always wear your personal protective clothing when performing
maintenance and cleaning work.
Remove any adhering welding spatter.
Ensure that all threaded fittings are tight.