13. Technical data
Power supply 11.5 - 14 V DC
Power consumption Standby: 35 mA / 12 V DC
During operation: 70 mA / 12 V DC
Inputs 4 positive / negative trigger inputs (5 - 28 V
DC)
Output 1 transistor output (OP), negative switching,
maximum current flow = 100 mA
Tamper NC alarm contact (for tamper loops only)
Dialling mode DTMF (tone dialling) and pulse dialling
Operating
temperature
-10 °C to 55 °C
Weight 360 g
Dimensions 150 mm x 115 mm x 30 mm (WxHxD)

Table of Contents