EasyManua.ls Logo

Acromag Vertu Series User Manual

Acromag Vertu Series
47 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Vertu Series VPM3000 Process Meters
& Temperature Transmitters
Instruction Manual
ACROMAG INC.
30765 S Wixom Road • Wixom MI 48393 USA
Tel (248) 624-1541 www.acromag.com
8501-180
1/8 DIN Digital Panel Meter with NEMA 4X, IP65 Front
4-20 mA, ± 10 V, TC & RTD Field Selectable Inputs
Easy Field Scaling in Engineering Units without Applying an Input
Full 4-Digit Display, 1.20" (30.5 mm)
Shallow Depth Case Extends Only 3.6" (91 mm) Behind Panel
Isolated 24 VDC @ 200 mA Transmitter Power Supply Option
2 Relays + Isolated 4-20 mA Output Options
Free PC-Based DisplayWizard Programming & Monitoring Software
No Assembly Required
Sunlight Readable Display
Operating Temperature Range: -40 to 65°C (-40 to 149°F)
UL & C-UL Listed. E244293; UL 508 Industrial Control Equipment
Input Power Options: 85-265 VAC / 90-265 VDC or 12-36 VDC / 12-24 VAC
Duplex Pump Controller with Alternation Capability
External Contacts for Remote Button Operation
USB, RS-232, & RS-485 Serial Communication Adapters Options
Modbus RTU Communication Protocol Standard
Copy Meter Settings to Other Vertu Meters
Password Protection
Max/Min Display
High & Low Alarms with Multiple Reset Actions
3-Year Warranty

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Acromag Vertu Series and is the answer not in the manual?

Acromag Vertu Series Specifications

General IconGeneral
SeriesVertu
Input Range±10V, 0-20mA
Resolution16-bit
Communication InterfaceEthernet
Operating Temperature-40°C to 70°C
Enclosure RatingIP20

Summary

Product Overview and Specifications

Introduction to Vertu VPM3000

Versatile meter for process/temp applications, shallow depth, NEMA 4X front panel.

Product Specifications

Detailed technical specifications for general, process input, and temperature inputs.

Installation and Connections

Panel Mounting Procedure

Steps for preparing the panel, mounting brackets, and securing the meter.

Wiring and Connections Guide

Guide to connector labeling and terminal connections for various meter configurations.

Signal Input Connections

Diagrams and instructions for connecting voltage, current, RTD, and thermocouple signals.

Setup, Operation, and Software

Setup Menu and Navigation

How to navigate the meter's setup menu using front panel buttons.

Scaling and Calibration Procedures

Procedures for scaling meter display and calibrating input signals.

Relay and Alarm Configuration

Setting relay action, set points, fail-safe, and time delays for alarms.

DisplayWizard Software Overview

Introduction to the software for remote programming, monitoring, and data acquisition.

Meter Operation and Max/Min Readings

How to operate the meter, view Max/Min readings, and use front panel buttons.

Troubleshooting, Compliance, and Support

Troubleshooting Tips

Common issues and solutions for meter operation and communication problems.

Factory Defaults and Reset Procedure

Procedure for resetting the meter to factory default settings.

Safety and Compliance Information

Important safety warnings, compliance information, and EU directives.

Contact and Support Information

Contact details for Acromag support and manual download information.