TUNING THE CONTROL LOOPS 6-23
SB1391 Hardware and Setup Guide - Document revision no. 1.14
FIGURE 6-16 Position error profile when AF=0
FIGURE 6-17 Position error profile when AF=500
Action
Increase AF until the error is minimized. (If AF is too large, the error may be excessive,
causing more motor noise.)