5.2.4 Setting of basic parameter (Pulse position command input)
The factory setting is 「Pulse position command input」. It is necessary to set the following parameters if the drive is driven by
pulse position command input.
Table 5.2.4 Parameter of control mode (Pulse position command input)
Select one in the following (Note 1)
“0”: Pulse / direction
“1”: Orthogonal phase difference
“2”: CCW/CW
Command division and multiplication (Numerator)
Command division and multiplication (Denominator)
Set to “(The number of output pulse of host control
mode)/4” (Note 2)
Note 1: Pulse command input list is shown in the following table.
Table 5.2.5 Pulse command input list
Parameter
No.32.0 pulse
command input
mode
The minimum necessary time range (t1, t2, t3, t4, t5, t6)
Pulse ·direction
Command pulse
Pulse
CMD_PLS
Direction
CMD_DIR
AB-phase
orthogonal phase
pulse
A-phase
CMD_PLS
B-phase
CMD-DIR
Note 2: Set when 1-rotation pulse (131,072) of host control device and drive is different. For details, refer to 「Chapter 4
Parameter list」.
Set the following parameters according to the using status.
Table 5.2.6 Parameter for pulse train position command input
Pulse train command input Rotation direction
For details, refer to 5.2.7.
Selection of Pulse train input logic
Select the logic of pulse train
Pulse train command - Input filter selection
Reduce the misoperation caused by input
command pulse interference.