After click [Communication setting] button, click [Disconnect] to disconnect the communication with the
servo drive.
Switch off the control power to the drive and restart.
The change status will not be displayed before restarting the control power supply.
Note 1: The control power for models of 750W or less is supplied from external 24VDC.For 1kW or more, is supplied from
internal. Therefore, the control power for models of 1kW or more can be ON/OFF by switching on/off the AC power supply of
main circuit.
5.2 Position control mode (Pulse position command input)
5.2.1 Wiring for user I/O connector (CN1) (Differential input)
User I/O
●24V power
supply input
●Parallel I/O
●Pulse command
input
●ABZ output
Drive control power supply 24V input
Drive control power supply GND
I/O power supply 24V input
Command input restriction
Deviation counter clear input
CCW drive input restriction
CW drive input restriction
Position completion output
Encoder Z-phase output (open collector)