Troubleshooting 2 (Servo not ON)
Even though is displayed on the setting panel, the servo cannot start.
Table 6.3.2
Cause
What to do
There is no servo ON(SVON) signal input.
Input SVON signal of host control device to the user I/O connector.
Alarm No.15 occurs.
There is no 200V AC input.
Make sure CHARGE LED is ON. If not, check if the 200V AC input
connector(L1/L2/L3) is loosen or the 200V AC is output or not.
Alarm No.15 occurs.
There is no main circuit power input in
multi-axial drive.
Connect the main circuit power supply.
The motor power output connector (U/V/W)
loosen.
Check the connection and make sure its OK.
Make sure if its connected in accordance with the connector installing
method in the users manual.
Drive itself failure.
Consult with ACTION TECHNOLOGY.
Troubleshooting 3 (Motor cannot rotate)
The servo is ON, but the motor will not operate.
Table 6.3.3
Cause
What to do
Wrong parameter setting.
For setting all the basic parameters in all control modes, refer to chapter 5
Table 5.2.4, Table 5.3.2, Table 5.4.2 and Table 5.5.2.
Do not input correct host commands.
Check the command input from host control device. Confirm the input
command is correct or not according to the waveform input by pulse train
command (position) or analog speed command in HCX-SETUP. Check the
parameter, such as division and multiplication. Sometimes, the motor
rotates quite slowly.
The connection of user I/O connector is not
correct.
For correct connection, refer to Figure 5.2.1, Figure 5.2.2, Figure 5.2.3,
Figure 5.3.1, Figure5.4.1 and Figure 5.5.1.
Command input is restricted.
Disconnect the HOLD and COM- of user I/O connector.
Torque command limit setting is not correct.
Set parameter No.147.0 and 148.0 correctly when using torque command
limit.
CCW/CW drive restriction input becomes
effective.
Set the parameter No.67.0 to 0 when not using CCW/CW drive
restriction input. CCWL, CWL and COM- of user I/O connector should be
closed when using CCW/CW drive restriction input.
Troubleshooting 4 (Motor operation is not steady)
The motor operates unsteadily.
Table 6.3.4
Cause
What to do
FG and GND connection is wrong.
Connect FG and GND correctly.