Table 5.7.2 I/O input signal
Signal
name
Contents
Function
Control mode
P
S
T
SVON
Servo ON
Servo is ON when connecting COM-.
RESET
Alarm reset
Reset alarms when connecting to COM-.
But if alarm occurs in encoder, model No. and system, this signal cannot be used to reset, and
drive control power supply must be restarted(OFFON).
HOLD
Command
input
restriction
When COM- connected, command input is restricted.
If not connected, command input are permitted.
Even if pulse is input, the motor cannot operate until the host control device allows command
input.
When Command input prohibited, whether to clear pulse counter can be set by parameter
No.67.3(the selection of position deviation counter in drive input)
When the speed command value is 0 in speed control mode, the motor will not operate.
PCLR
Deviation
counter clear
When COM- connected, position deviation counter will be cleared.
-
-
CCWL
CCW drive
restriction
If COM- disconnected, CCW direction drive is prohibited.
If the value is beyond the CCW direction movement range, please make the wiring which can
be disconnected with COM-.
It is effective when 2: Enable CCW-drive restrictionor3: Enable CW/CCW-drive restriction
is selected in parameter No.67.0Selection of Drive restriction options. Initial value: 0:
Disable
The deceleration can be selected in parameter No.67.1 Deceleration method selection when
Drive restriction is enabled . Initial value: 1: Short brake.
After-stop state can be selected in parameter No.67.2 Selection for Stop condition when
Drive restriction is enabled. Initial value: 0: Free-run
Parameter No.67.3 Selection for Location deviation counter option when Drive restriction is
enabledcan be set to hold the position deviation counter. Initial value: 0: Keep
CWL
CW drive
restriction
If COM- disconnected, CW direction drive is prohibited.
If the value is beyond the CW direction movement range, please make the wiring which can be
disconnected with COM-.
It is effective when 2: Enable CW-drive restrictionor3: Enable CW/CCW-drive restriction
is selected in parameter No.67.0Selection of Drive restriction options. Initial value: 0:
Disable
The deceleration can be selected in parameter No.67.1 Deceleration method selection when

Table of Contents