The Status monitoring mode on the setting panel can be used to confirm whether a regenerative resistor is needed. Select
「St_REG」on the setting panel to display 「in00_-」. When the display changes from 「in00_-」 to 「in00_A」, it means the
regenerative resistor is needed. For details, refer to [5.4 Status display mode [Regenerative resistor]].
Starting from low speed operation (20% of the max. speed) to the desired operation and observing if the display value
changes from 「in00_-」 to 「in00_A」 If 「in00_A」displays, a regenerative resistor is needed.
If the regenerative resistor is needed, refer to the installation of regenerative resistor. The use of regenerative resistor cannot
necessarily guarantee the performance. When heating temperature is too high, please increase the resistance, or the
permissible power.