Adept Lynx Platform User's Guide, Rev D
Page 25 of 126
Chapter 2: Setup
2.4 Repacking for Relocation
If the platform or other equipment needs to be relocated, reverse the steps in the installation
procedures in this chapter. Reuse the original packing crate and materials and follow all safety
notes used for installation. Improper packaging for shipment will void your warranty.
The platform must always be shipped in an upright orientation.
2.5 Operating Environment
The Adept Lynx platform is designed to operate in an environment that is wheelchair access-
ible. Care must be taken to avoid:
l glass doors and walls
l pits without railings or low bumpers
l floors with access panels removed
l loose cables, hoses, etc.
l large, highly-reflective objects
Floors must provide good traction, typical of good walking conditions.
l Slope
up to 1:12
l Step traversal
up to 15 mm (0.6 in.)
l Gap traversal
up to 15 mm (0.6 in.)
l Temperature
5° to 40° C (41° to 104° F)
l Humidity
5 to 95%, non-condensing
The Adept Lynx platform is not intended for use in hazardous environments (explosive gas,
water, dust, oil mist). It has an IP rating of IP-40.
WARNING: Do not allow the platform to drive through an opening that
has an automatic gate/door unless the door and platform are configured
correctly with the Lynx Door Box option.
Refer to the Adept Lynx Platform Peripherals Guide for details on the
Adept Lynx Door Box.
2.6 Installing a Lynx System
Installing the Battery
Your Adept Lynx platform comes fully-assembled, battery fully-charged.
NOTE:Air shipping regulations require that the platform be shipped without the
battery installed.