61
Communication address description
0 : Clear communication loss and communication error fault relay.
1 : CW.
2 : CCW.
3 : Stop.
Note : This is last operating command value and it is not real
motor running condition.
This parameter is real motor speed value. Use RS485 protocol
03H to read motor speed.
RS485 operating
command
100
Setting Range 0 ~ 3
Motor speed
(RPM)
101
RS485 speed
command
28,29,34,35
Close loop speed command :
Setting range is 0 ~ 9999.
CF OFF, CD28(1CH) content.
CF ON, CD29(1DH) content.
Open loop speed command :
Setting range is 0 ~ 1000.
CF OFF, CD34(22H) content.
CF ON, CD35(23H) content.

Related product manuals