283 ADAM-4000 Series User Manual
Appendix A Technical Specifications
Table A.4: ADAM-4011D Range Accuracy for Thermocouple
Range Code (Hex) Input Range Typical Accuracy Maximum Error Units
0E
J thermocouple
0 to760 °C
±0.5 ±0.75 °C
0F
K thermocouple
0 to 1370 °C
±0.5 ±0.75 °C
10
T thermocouple
-100 to 400 °C
±0.5 ±0.75 °C
11
E thermocouple
0 to 1000 °C
±0.5 ±0.75 °C
12
R thermocouple
500 to 1750 °C
±0.6 ±1.5 °C
13
S thermocouple
500 to 1750 °C
±0.6 ±1.5 °C
14
B thermocouple
500 to 1800 °C
±1.2 ±2.0 °C

Table of Contents