ADAM-6100PN Series User Manual 12
3.1.2 Specifications
Digital Input
Channels:
– ADAM-6150PN: 8
– ADAM-6151PN: 16
Dry Contact (Switch: ON):
– Logic level 0: Open
– Logic level 1: Close to DGND
Wet Contact (Switch: OFF):
– Logic level 0: 0 ~ 3 V
DC or
0 ~ -3V
DC
– Logic level 1: 10 ~ 30 V
DC
or -10 ~ -30 V
DC
Input Impedance: 10 kΩ
Transition Time: 0.2 ms
Digital Output
Channels:
– ADAM-6150PN: 7
– ADAM-6156PN: 16
Output Voltage Range: 8 ~ 35 V
DC
Normal Output Current: 100 mA (per channel)
FSV Safety Function
General
Communication: 10/100 Base-T Ethernet
Supported Protocol: PROFINET
Power Input: Unregulated 10 ~ 30 V
DC
Power Consumption: 2.4 W @ 24 V
DC
Power Reversal Protection (30V Max.)
Operating Humidity: 20 ~ 95% RH (non-condensing)
Storage Humidity: 0 ~ 95% RH (non-condensing)
Operating Temperature: -10 ~ 70°C
Storage Temperature: -20 ~ 80°C