Do you have a question about the AGFA DX-D 600 and is the answer not in the manual?
Type | Digital Radiography System |
---|---|
Detector Type | Wireless Flat Panel Detector |
Wireless Communication | IEEE 802.11a/b/g/n |
Power Requirements | 100-240 VAC, 50/60 Hz |
Image Acquisition | Digital |
Connectivity | Wireless (Wi-Fi) |
Detector Technology | Amorphous Silicon (a-Si) |
Battery Type | Lithium Ion |
Image Matrix | 3072 x 3072 |
Data Acquisition Time | <5 seconds |
General overview of the DX-D 600 X-ray System and its configurations.
Details system configurations (Double Panel, Single Panel) and components.
Highlights key features of the X-ray System.
Explains identification labels and information on equipment.
Details intended use, normal use, and contraindications.
Lists parts that come into physical contact with the patient.
General safety precautions for operation and service.
Outlines responsibilities of manufacturer, user, and operator.
Information on dose limits and training requirements.
Guidelines on protecting personnel and patients from radiation.
Methods for monitoring radiation exposure of personnel.
Explains safety symbols used on the equipment.
Details regulatory compliance and statements.
Information on EMC emissions and immunity.
Step-by-step guide to powering on the X-ray system.
Step-by-step guide for powering off the X-ray system.
Overview of the touchscreen interface and its areas.
General warnings and procedures for moving the ceiling suspension.
Steps for aligning the X-ray beam with the patient and receptor.
Safety rules and procedures for patient positioning on the table.
How to move the tabletop (horizontal and vertical).
How to move the DR detector horizontally.
Procedure for loading a portable DR detector.
How to load and remove grids from the RAD table.
Information on accessories for the RAD table.
General warnings and procedures for wall stand movements.
How to operate the footswitch for vertical detector movement.
Safety warnings and procedures for tilting the DR detector.
How to rotate the DR detector and important considerations.
How to align the X-ray tube with the DR detector.
Procedure for loading a portable DR detector.
Daily checks and maintenance for the DR detector.
How to load and remove grids from the wall stand.
Information on accessories for the wall stand.
Overview of the Ralco R225 automatic collimator controls.
Controls for the Ralco manual collimator.
Information on compatible dosimeter devices.
Troubleshooting specific to the RAD Wall Stand DR.
Troubleshooting specific to the RAD Table.
Troubleshooting specific to the ceiling suspension.
Lists and explains software error messages.
The procedure for starting up the system.
Recommended procedure for warming up the X-ray tube.
General steps for performing radiographic examinations.
How to use the Automatic Exposure Control (AEC).
Maintenance tasks to be performed by the operator.
Maintenance tasks for qualified service personnel.
Specifies operating and storage environmental conditions.
Details power line requirements for system components.
Technical specifications for the X-ray generator.
Specifications for different X-ray tube models.
Specifications for collimator models.