72
Configuring the Station
2.3.3 Miscellaneous
Register Transmission Interval [sec]♦
DTMF digit interval timeout [sec]♦
Call health check timer♦
Description Configure the interval at which to send Register to the IP-PBX.
Settings 10-14400 sec
Default values 3600 sec
Description Configure the time to timeout signal reception, when a DTMF signal is not received from the VoIP
Phone for a continuous period of time.
Settings 1 - 10 sec
Default values 5 sec
Description When a communication error occurs during a call or while monitoring, the connection is
disconnected after the specified time elapses.
Settings 80 - 3600 sec: Select when configuring a value from 80 to 3600 sec.
Do not transmit re-INVITE: Do not detect communication errors.
Default values 90 sec.