90
Settings and Adjustments
Configuring on the station
4
Monitor Assign the monitoring or
scan monitoring function to
the Speed Dial button.
Scan monitoring cannot be
assigned unless scan
monitoring is configured in
“Monitor (page 82)”.
Refer to
“How to configure
Speed Dial Settings
(page 112)” for how to
configure this.
--
Relay Control Assign optional relay (a
function that controls the
output terminal of another
station) to the Speed Dial
button.
Refer to
“How to configure
Speed Dial Settings
(page 112)” for how to
configure this.
--
RANGE
(TIMER)
Select the Output Time
Range for relay output, and
set the Timer within the
range.
Momentary: The relay
continues to output
when the Speed Dial
button is pressed.
Pressing the Speed
Dial button again stops
relay output.
200 to 2000 msec:
Select this to set a
time between 200 and
2000 msec (by 200
msec).
Enter the time in
"TIMER."
3 to 600 sec: Select
this to set a time
between 3 and 600
sec (by 1 sec). Enter
the time in "TIMER."
Momentary
Edit Name Set the name of the Speed
Dial button.
1-24 alphanumeric
characters (Configure
"Button Name" of the
IXG Support Tool
Settings if inputting full-
width characters.) The
set name is displayed on
the Speed Dial.
The entire name may not
be displayed, depending
on the type of Home
screen and number of
characters.
-
Entry Description Settings Default values