Configuring the Station
3.2.1 Relay Output Advanced Settings
How to configure Relay Output
1. Select the relay output to configure in "Relay Output #."
• The settings of the selected relay output will be displayed.
2. Configure each item.
3. Click [Update].
■ Function
■ SIF Origination Station Number
■ Option Relay Control
■ Output Time Range
Description Select the function of the Relay Output.
Settings • No Function
• Bathroom Indicator: Not used.
• Contact Change SIF Event: Relay output when Contact Change SIF Event is received from
another station. Output Time is the same as Option Input Detection Time or Relay Output Time
of the SIF command originating station. Configuration can be set in "How to configure Contact
Change SIF Event".
Default values No Function
Description If “Function (→page 67)” is set to "Contact Change SIF Event", enter the SIF Origination Station
Number.
Settings 3-5 digits
Default values -
Description Select Enable / Disable for Option Relay Control when using the speed dial of IX-MV7-* to
control the output. If
“Function (→page 67)” is set to "No Function" and this is set to "Enable," this
can be controlled as option relay. The output time will be the output time configured in IX-MV7-*.
Settings • Enable
• Disable
Default values Disable
Description
Configure the output time of the relay output when the output terminal is controlled via “CGI
(→page 78)”.
Settings • 200 - 2000 [msec]: Select when configuring a value from 200 to 2000 msec (by 200 msec).
Enter the time in "Output Time [msec / sec]♦."
• 3 - 600 [sec]: Select when setting a value from 3 to 600 sec (by 1 sec).
Enter the time in "Output Time [msec / sec]♦."
Default values 400 msec