81
Configuring the Station
4.4.4 Transmission Trigger
Configure the SIF sending trigger when “Program Type (→page 80)” is set to "0010" or "0100-1111."
Change contact
Unit error
Periodical Transmission
Initialization Notice
4.4.5 Periodical Transmission Interval
Periodical Transmission Interval♦
Description Send SIF command when Option Input contact or Relay Output contact is changed.
Settings Checked: Send
Unchecked: Do not send
Default values Unchecked: Do not send
Description Send SIF command when communication error has occurred.
Settings Checked: Send
Unchecked: Do not send
Default values Unchecked: Do not send
Description Periodically send the station status using SIF command. The interval is set in “Periodical
Transmission Interval (→page 81)”.
Settings Checked: Send
Unchecked: Do not send
Default values Unchecked: Do not send
Description Send SIF command when the station is booted.
Settings Checked: Send
Unchecked: Do not send
Default values Unchecked: Do not send
Description Set the interval to send the station status periodically using SIF command in “Periodical
Transmission (→page 81)”.
Settings 0 (Do not send) - 1440 (min)
1 - 59 (sec): Enter 10001 - 10059 when setting 1 - 59 sec.
Default values 0 (do not send)