21
Diagnostics Menu Options
SENSOR DATA shows the scale’s A/D, or analog-to-digital,
readings, which indicate whether the scale is reading weight. In
general, an A/D reading of 409 indicates 0 pounds of weight; an
A/D reading of 750-1250 is about normal for an empty bin in the lift
zone; and an A/D reading of at least 200 points higher than your
empty bin in the lift zone is about normal for a full bin in the lift zone.
SENSOR DATA also shows the current low and high prox sensor
values(press▼oncetoaccessproxsensorvaluesonceyoureach
SENSOR DATA). When the prox sensor target is not engaged, as
when the arms of the scale are completely lowered, the value will be
0. When the target is engaged, the value will be three to four digits.
CALIB DATA shows the A/D readings for the scale at the time of
calibration. It also shows weight, ratio and offset for empty and
heavy weights at the time of calibration. This can help you tell
whether you calibrated the scale incorrectly.
Troubleshooting | Navigating Diagnostics Menu