EasyManua.ls Logo

Alcatel-Lucent OmniSwitch 6250 - Monitoring the Stack; CLI Commands Used for Monitoring a Stack

Alcatel-Lucent OmniSwitch 6250
176 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Managing OmniSwitch 6250 Stacks Monitoring the Stack
OmniSwitch 6250 Hardware Users Guide September 2015 page 7-41
Monitoring the Stack
As shown in the previous sections, monitoring the current status and operation of all elements in a stack
can help users avoid unexpected stack conditions. The table below includes CLI commands that are useful
in monitoring stack conditions.
CLI Commands Used for Monitoring a Stack
show stack topology Displays the current operating topology of switches within a
stack.
show stack status Displays the current redundant stacking cable status.
show running-directory Displays the directory from where the switch was booted. This
command also shows important information, including
whether the software across the stack is synchronized.
show chassis Displays basic configuration and status information for the
switch
chassis.
show cmm Displays basic hardware and status information for primary
and
secondary management modules operating in the stack.
show ni Displays basic hardware and status information for modules
currently operating in the stack.
show module Displays basic information for modules installed in the stack.
Modules include primary and secondary management modules
and any modules operating in idle status.
show module long Displays detailed information for modules installed in the
stack. Modules include primary and secondary management
modules and any modules operating in idle status.
show module status Displays basic status information for modules installed in the
stack. Modules include primary and secondary management
modules and any modules operating in idle status.
show power Displays hardware information and current status for chassis
power supplies. This includes the status of backup power sup-
plies, if applicable.
show fan Displays the current operating status of each of the six fans
operating in each chassis.
show temperature Displays the current operating chassis ambient temperature, as
well as current temperature threshold settings for each of the
modules in the stack.
show stack split-protection status This command displays all the information related to SSP
when enabled.
show stack split-protection statistics This command shows statistics of stack split-protection.
show stack split-protection stacking-
units
This command shows the SSP state of all stacked units.

Table of Contents

Other manuals for Alcatel-Lucent OmniSwitch 6250

Related product manuals